Page 6
3000 MANUAL - FORM 3000-003
02/07
MODEL 3000 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
MOUNTING THE LOCK
Any roughed-in wiring may be brought in at this time through the slotted wiring holes. Re-install the lock on the Fas-
Trak. Firmly tighten both housing set screws with the 1/8” ball head hex wrench. Replace End Cover. Continue
with wiring, see separate instruction booklet. If the lock wiring is not being done at this time replace the Access
Cover and see that all instructions are left for the electrical installer.
Before installation begins remove the End Cover and Access
Cover (see page 7 for parts locations). In the upper inside corners
of the lock housing are located two #1/4-28 set screws. Using the
1/8” ball head hex wrench loosen (do not remove) the two set
screws until the Fas-Trak Baseplate is free (Fig. “C”). Remove
the Fas-Trak.
Place the Fas-Trak against the header with the slot counter-bores
visible and the tabs facing the door (Fig. “A”). Attach the Fas-
Trak to the header at both slotted hole locations, with two #10 x
1” tek screws or two 10-24 x 1/2” machine screws, if the frame
has been reinforced and may be tapped. Tighten the screws just
snug enough to allow for fi nal adjustment.
Temporarily mount the lock to the Fas-Trak by offsetting the lock
1-1/8” from the jamb (Fig. “C”) and tipping the front of the lock
down engaging the rear fl ange of the Fas-Trak (Fig. “B”). Rotate
the lock up allowing one tab to pass through the corresponding
notch in the top of the lock housing. Slide the lock into position.
Close and latch the door. Check that the armature and lock
faces make full contact.
Make sure the door hits the frame
just before the maglock (not slamming on the lock)
. If any
adjustment is required gently tap the housing with a soft mallet.
Open the door, remove the lock from the Fas-Trak and tighten
both slot screws. Drive three #10 x 1” tek screws into the header
using the Fas-Trak as a physical template. Screw heads must
not project above the Fas-Trak.
1.
2.
3.
4.
FAS-TRAK
TABS
SET
SCREW
LOCK
VERTICAL JAMB
FIG. “C”
1-1/8” OFFSET
TABS FACING DOOR
VISIBLE SLOT
COUNTER-BORES
LOCK
ENGAGE
REAR
FLANGE
FAS-TRAK
FIG. “B”
FIG. “A”
SET
SCREW
Comentarios a estos manuales