Page 5
3000 MANUAL - FORM 3000-003
02/07
MODEL 3000 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
CONVERTING LOCK HANDING
The 3000 is factory confi gured to RHRB door handing. To convert the lock to LHRB handing complete the
following steps.
Remove the access and end covers. Using
the 1/8” ball end hex wrench provided,
loosen both housing set screws approx.
three turns. Do not remove the set screws
from the housing.
Slide the FasTrak mounting baseplate off
the housing. Remove the six phillips head
coil mounting screws on the top and bottom
of the housing. Carefully remove the coil
assembly. Avoid pulling on the coil wires.
Rotate the coil assembly 180 degrees and
re-install into the housing, with the inactive
end against the right coil stop. Re-install the
six coil mounting screws and fi rmly tighten.
Re-install the access and end covers in
their new positions.
HOUSING
SET SCREWS
END COVER
ACCESS COVER
FAS-TRAK
REMOVE COIL
MOUNTING SCREWS
(6 PCS.)
INACTIVE COIL
END
RIGHT COIL STOP
COIL ASSY.
RE-INSTALL COIL
MOUNTING SCREWS
(6 PCS.)
END
COVER
ACCESS COVER
A.
B.